View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: CyberPower Equipment: PowerPanel Vulnerabilities: Use of Hard-coded Password, Relative Path Traversal, Use of Hard-coded Credentials, Active Debug Code, Storing Passwords in a Recoverable Format, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Use of Hard-coded Cryptographic Key, […]
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity […]
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: MACH SCM Vulnerabilities: Improper Control of Generation of Code, Improper Neutralization of Directives in Dynamically Evaluated Code 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an execution of arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The […]
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow the attacker to upload or transfer files of dangerous types that can be automatically processed within the product's […]
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Unitronics Equipment: Vision Legacy series Vulnerability: Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to log in to the Remote HMI feature, where the PLC may be factory reset, stopped, and […]
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.8 ATTENTION: Low attack complexity Vendor: Measuresoft Equipment: ScadaPro Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges from unprivileged to SYSTEM privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ScadaPro, a supervisory control […]
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix 5580, GuardLogix 5580, CompactLogix 5380, 1756-EN4TR Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a major nonrecoverable fault (MNRF) resulting in the product to become unavailable. 3. […]